Product Description:
3M™ Fire Barrier Duct Wrap 615 is a fire resistant wrap consisting of a bio-soluble ceramic fiber blanket encapsulated with a scrim-reinforced foil. As a single layer fire resistant wrap, it has passed ISO 6944 ‘Fire Resistance Tests – Ventilation Ducts’. This non-asbestos wrap contains a safer fiber construction and installs easily because of its high flexibility and strength. With its excellent insulating capabilities, low weight and thin profile, it is an ideal choice for a duct enclosure system.
Features:
- One layer wrap for ventilation ducts
- High flexibility for installation ease
- Thin and lightweight
- Nominal 6pcf density
- Foil encapsulated for blanket protection, less dust and high wrap strength
- Center stitched for ease of handling and banding location
- Safer fiber construction
Applications:
3M™ Fire Barrier Duct Wrap 615 is an ideal fire resistive enclosure for life safety system ducts. These duct systems are in place to allow occupants to safely leave a building in fire scenario. Dampers are frequently omitted from life safety ducts. 3M™ Fire Barrier Duct Wrap 615 installed around the duct creates a fire-resistive enclosure that maintains the integrity of the duct and prevents the passage of fire from one compartment to the next. Compared to conventional gypsum enclosures, 3M™ Fire Barrier Duct Wrap 615 is lighter weight, requires less space and typically has lower installation costs. It is a proven alternative to a 1- or 2-hour fire resistant rated shaft enclosure in protecting ventilation ducts as tested per ISO 6944-85 ‘Fire Resistance Tests – Ventilation Ducts’.
Some smoke-control methods commonly used to achieve life safety objectives are:
- Mechanical Smoke Exhaust
- Stairwell Pressurization
- Ventilated Vestibules
- Zoned Smoke Control
- Elevator Smoke Control
- Smokeproof Enclosures with Mechanical Ventilation
- Engineered Ventilation Systems
Code Compliance:
- 3M™ Fire Barrier Duct Wrap 615 can be used to comply with requirements of the following codes:
- NFPA 92A Standard for Smoke-Control System Utilizing Barriers and Pressure Differences, 2006 Edition – Section 6.6.2
- NFPA 92B Standard for Smoke Management Systems in Malls, Atria, and Large Spaces, 2005 Edition – Section 7.5.2• NFPA 101® Life Safety Code®, 2006 Edition – Section(s) 8.6.7, 18.7.7
- International Mechanical Code®, 2006 Edition – Section 513.10.2
- International Building Code®, 2006 Edition – Section 909.10.2
Performance:
3M™ Fire Barrier Duct Wrap 615 has been tested in accordance with the following:
ISO 6944, ASTM E 84, ULC/CAN S 102, ASTM E 814, UL 1479, ASTM C 1338, ASTM C 411, ASTM C 518